AAA Products International Inc.
7114 Harry Hines Blvd.
Dallas, Texas 75235
214-357-3851

Classic Operators & Coils

"Classic" Operator & Coil - Standard

The "Classic" solenoid operators sturdy and tough construction with a 1/2" NPT conduit connection. The stem exhaust is tapped 10-32. Voltage must be specified when ordering valves that use this operator. If no voltage is specified, then 120/60 is provided. Other voltages not shown below are available. Coil can be rotated in any direction on operator stem when space is available. Caution must be used when rotating coil so not to untighten the stem from the adaptor block. Standard leads are 18", longer leads available on request. When connecting to an electrical source either black wire can be connected to hot (+) and the other connected to neutral (-).
Voltage Pick-Up Holding Resistance Operator Spare Coil*
24 volts, 60 Hz 1.72 amps 1.10 amps 5.39 ohms AY-38-4 V-67-4AY-38 AY-38
AY-38
120 volts, 60 Hz 0.36 amps 0.23 amps 135 ohms AY-38-11 V-67-11
240 volts, 60 Hz 0.18 amps 0.12 amps 546 ohms AY-38-17 V-67-17
12 volts D-C 1.20 amps 12.8 ohms AY-38-5 V-67-5
24 volts D-C 0.58 amps 61 ohms AY-38-8 V-67-8

Materials: Steel, stainless steel, thermoset polyester molded resin coil, Buna-N seat & O-Ring.
Repair Kit: RKPSV-1 includes plunger, spring & O-Ring.
Ambient Temperature: -4°F to +120°F.
Relative Duty Cycle: 100%.
Degree of Protection: NEMA 1.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Orifice Size: 3/64" base, 1/16" stem.
Insulation Class: B
*Coils: The encapsulated coils are UL approved. The coil is marked or embossed with QC130, QC155, or QC180. UL Document.

"Classic" Operator & Coil - Standard w/Tapped Exhaust

The "Classic" solenoid operators sturdy and tough construction with a 1/2" NPT conduit connection. The stem exhaust is tapped 1/8" NPTF. Voltage must be specified when ordering valves that use this operator. If no voltage is specified, then 120/60 is provided. Other voltages not shown below are available. Coil can be rotated in any direction on operator stem when space is available. Caution must be used when rotating coil so not to untighten the stem from the adaptor block. Standard leads are 18", longer leads available on request. When connecting to an electrical source either black wire can be connected to hot (+) and the other connected to neutral (-).
Voltage Pick-Up Holding Resistance Operator Spare Coil*
24 volts, 60 Hz 1.72 amps 1.10 amps 5.39 ohms AY-38T-4 V-67-4AY-38T AY-38T
AY-38
120 volts, 60 Hz 0.36 amps 0.23 amps 135 ohms AY-38T-11 V-67-11
240 volts, 60 Hz 0.18 amps 0.12 amps 546 ohms AY-38T-17 V-67-17
12 volts D-C 1.20 amps 12.8 ohms AY-38T-5 V-67-5
24 volts D-C 0.58 amps 61 ohms AY-38T-8 V-67-8

Materials: Steel, stainless steel, thermoset polyester molded resin coil, Buna-N seat & O-Ring.
Repair Kit: RKPSV-1 includes plunger, spring & O-Ring.
Ambient Temperature: -4°F to +120°F.
Relative Duty Cycle: 100%.
Degree of Protection: NEMA 1.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Orifice Size: 3/64" base, 1/16" stem.
Insulation Class: B
*Coils: The encapsulated coils are UL approved. The coil is marked or embossed with QC130, QC155, or QC180. UL Document.

"Classic" Operator & Coil - DIN Style

The "Classic" DIN solenoid operator with a ISO 4400 din pattern connection (Form A, DIN 43650-A, 18 mm contact distance). DIN caps are ordered as a separate line item. The stem exhaust is tapped 10-32. Voltage must be specified when ordering valves that use this operator. If no voltage is specified, then 120/60 is provided. Other voltages not shown below are available. Coil can be rotated in any direction on operator stem when space is available. Caution must be used when rotating coil so not to untighten the stem from the adaptor block. An approved cap must be used when connecting to an electrical source. The longer tab is the ground (earth). Either shorter tab can be connected to hot (+) and the other connected to neutral (-).
Voltage Pick-Up Holding Resistance Operator Spare Coil*
120 volts, 60 Hz 0.36 amps 0.23 amps 135 ohms AY-38ED-11 V-67ED-11AY-38ED AY-38ED
AY-38ED
240 volts, 60 Hz 0.18 amps 0.12 amps 546 ohms AY-38ED-17 V-67ED-17
12 volts D-C 1.20 amps 12.8 ohms AY-38ED-5 V-67ED-5
24 volts D-C 0.58 amps 61 ohms AY-38ED-8 V-67ED-8

Materials: Duroplast/thermoset resin, Buna-N seat & O-Ring.
Repair Kit: RKPSV-1 includes plunger, spring & O-Ring.
Ambient Temperature: -4°F to +120°F.
Relative Duty Cycle: 100%.
Degree of Protection: NEMA 4 & 4X with connector.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Orifice Size: 3/64" base, 1/16" stem.
*Coils: The encapsulated coils are UL approved. The coil is marked or embossed with QC130, QC155, or QC180. UL Document.

"Classic" Operator & Coil - Explosion Proof

The "Classic" explosion proof solenoid operators are sturdy and tough construction with a 1/2" NPT conduit connection. The stem exhaust is tapped 1/8"-27 NPT. Voltage must be specified when ordering valves that use this operator. If no voltage is specified, then 120/60 is provided. Other voltages not shown below are available. Coil can be rotated in any direction on operator stem when space is available. Caution must be used when rotating coil so not to untighten the stem from the adaptor block. The explosion proof operator carries the UL & CSA label for Class I, Division 1, Group C and D (gasoline vapors, etc.), Class II, Division 1, Groups E, F and G (coal , coke and grain dusts). Temperature code: T4A. Standard leads are 18". When connecting to an electrical source either black wire can be connected to hot (+) and the other connected to neutral (-). The green wire is the ground (earth). The housing of all "Classic" explosion proof solenoids cannot be rotated or serviced in the field. If coil orientation is not specified at time of order, the 1/2" conduit will be rotated towards the 2 port side of valve body.
Voltage Pick-Up Holding Resistance
24 volts, 60 Hz 1.72 amps 1.10 amps 5.39 ohms AY-38X AY-38X
AY-38X
120 volts, 60 Hz 0.36 amps 0.23 amps 135 ohms
240 volts, 60 Hz 0.18 amps 0.12 amps 546 ohms
12 volts D-C 1.20 amps 12.8 ohms
24 volts D-C 0.58 amps 61 ohms

Materials: Steel, stainless steel, thermoset polyester molded resin coil, Buna-N seat & O-Ring.
Ambient Temperature: -4°F to +120°F.
Relative Duty Cycle: 100%.
Certifications: UL & CSA label for Class I, Division 1, Group C and D, Class II, Division 1, Groups E, F and G. CSA file number 087427_0_000. UL file number E37005
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Orifice Size: 3/64" base, 1/16" stem.
Insulation Class: B


Commonly Asked Questions
Q: Can I use a piece of equipment approved for use in a Division 1 hazardous location in a Division 2 hazardous location?
A: Yes. If equipment has been approved for use in a Division 1 hazardous location, it can be used in a Division 2 hazardous location, providing it is in the same class and group.
Q: Can equipment approved for a Class I hazardous location be used in a Class II hazardous location?
A: No. Equipment used in Class I and Class II hazardous locations are made for different purposes. Equipment approved for Class I hazardous locations must contain an internal explosion, while Class II approved equipment must seal out dust. They are not interchangeable.

"Classic" Operator & Coil - Mold-Over

The "Classic" Mold-Over solenoid operator with a 1/2"-14 NPT conduit connection. The stem exhaust is tapped 10-32. Voltage must be specified when ordering valves that use this operator. If no voltage is specified, then 120/60 is provided. Other voltages not shown below are available. Coil can be rotated in any direction on operator stem when space is available. Caution must be used when rotating coil so not to untighten the stem from the adaptor block. Standard leads are 18", longer leads available on request. When connecting to an electrical source either black wire can be connected to hot (+) and the other connected to neutral (-). The green wire is the ground (earth).
Voltage Pick-Up Holding Resistance Operator Spare Coil*
120 volts, 60 Hz 0.36 amps 0.23 amps 135 ohms AY-38M-11 V-67M-11 AY-38M AY-38M
AY-38M
240 volts, 60 Hz 0.18 amps 0.12 amps 546 ohms AY-38M-17 V-67M-17
12 volts D-C 1.20 amps 12.8 ohms AY-38M-5 V-67M-5
24 volts D-C 0.58 amps 61 ohms AY-38M-8 V-67M-8

Materials: Zinc plated steel hub, molded coil, Buna-N seat & O-Ring.
Repair Kit: RKPSV-1 includes plunger, spring & O-Ring.
Ambient Temperature: -4°F to +120°F.
Relative Duty Cycle: 100%.
Degree of Protection: NEMA 4 & 4X.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Orifice Size: 3/64" base, 1/16" stem.
*Coils: The encapsulated coils are UL approved. The coil is marked or embossed with QC130, QC155, or QC180. UL Document.