Replacement Parts for Valves
For individual replacement parts see parts drawings on valve data page.
Replacement Parts
The repair kits are grouped by port size. All valves within the same port size use that same repair kit. A
single solenoid kit uses the same repair kit as a hand valve as long as they are the same port size. Each
repair kit includes Magnalube-G factory grease. Piston valves require an additional cylinder repair kit. 1-1/2" & 2"
valves with a piggy back valve, require an additional repair kit (ERKV-3) for the piggy back valve. A copy of the instructions sheet sent with each valve is available
here.
NOTE: To order a repair kit with DOW-55 lubricant, append a W to the valve body style, e.g. ERKV-3W.
To order a repair kit with different valve body O-Rings, append the O-Ring dash number, e.g. ERKV-3W-9
Body Style | Description | Kit Number |
---|---|---|
1/4" & 3/8" |
Includes 6 V-39 Viton body O-Rings, 3 EMG3 Buna-N solenoid gaskets, 2 ECG3 end cap gaskets, 2 V-565 Buna-N Namur mounting O-Rings, 1 PBG3 gasket, 1 PBG3-1 gasket, 3 V-110 Buna-N 'B'-Series section O-Rings, 5 V-92 Buna-N subplate O-Rings and 2 V-93 Buna-N subplate pilot O-Rings. | ERKV-3 |
1/2" | Includes 6 V-6 Buna-N body O-Rings, 2 EMG3 Buna-N solenoid gaskets, 2 ECG48 end cap gaskets, 5 V-110 Buna-N subplate O-Rings, 2 V-29 Buna-N subplate pilot hole O-Rings. | ERKV-4 |
3/4" & 1" |
Includes 6 V-30 Buna-N body O-Rings, 2 EMG3 Buna-N solenoid gaskets, 2 ECG48 end cap gaskets, 5 V-6 Buna-N subplate O-Rings, 2 V-89 Buna-N subplate pilot hole O-Rings. | ERKV-8 |
1-1/2" & 2" |
Includes 6 V-123 Buna-N body O-Rings, 2 V-124 Buna-N end cap O-Rings, 2 V-89 Buna-N end cap
pilot O-Rings, 5 V-125 Buna-N subplate O-Rings, 2 V-89 Buna-N subplate pilot O-Rings, 2
V-128 Buna-N O-Rings, 2 V-129 U-Cup seals. To repair piggy back valve, use an additional ERKV-3. |
ERKV-16 |
To order a repair kit with different valve body O-Rings, append the O-Ring dash number, e.g. ERKV-3W-9
Piston valves cylinder repair kits include all seals required for the piston part of a valve. On single
acting piston valves, there will be extra seals not used. An additional kit for the valve body repair kit is
required.Each repair kit includes Magnalube-G factory grease.
NOTE: To order a repair kit with DOW-55 lubricant, append a W to the valve body style, e.g. RKPV-3DW.
Body Style | Description | Kit Number |
---|---|---|
1/4" & 3/8" |
Includes 2 V-165 barrel gaskets, 2 V-115 U-Cups, 1 V-110 O-Ring and 1 V-89 O-Ring. | RKPV-3D |
1/2", 1" & 3/4" |
Includes 2 V-166 barrel gaskets, 2 V-102 U-Cups, 1 V-110 O-Ring and 1 V-89 O-Ring. | RKPV-48D |
Solenoid operator repair kits include seals, springs and plunger required for the solenoid operator part of
a valve.
Operator Style | Description | Kit Number |
---|---|---|
Classic | Includes one V-49 Buna-N plunger, one V-50 spring and one V-61 O-Ring. One kit required per solenoid operator. | RKPSV-1 |
Standard | There are no parts available to repair an operator, must order a new operator. | |
Standard V-550-1 solenoid operator with red push button non-locking override and EMG3 gasket. | ESPK | |
V-599-1 solenoid operator with a yellow twist locking override and EMG3 gasket. | ESPKO |
"E-Series" Coil - Standard
The standard coils are a DIN 43650-B style with a 11mm/Industrial Type B connector pin pattern (mini connector, 11 mm contact distance). DIN caps are ordered as a separate line item. Voltage must be specified when ordering. If no voltage is specified, then 120/60 is provided. Other voltages not shown below are available. Coil can be rotated in 90° increments on operator stem when space is available. An approved cap must be used when connecting to an electrical source. The longer tab is the ground (earth). Either shorter tab can be connected to hot (+) and the other connected to neutral (-).
Voltage | Pick-Up | Holding | Resistance | Spare Coil | |
---|---|---|---|---|---|
24 volts, 50/60 Hz | 7.1 VA | 5.8 VA | 27.4 ohms | ||
48 volts, 50/60 Hz | 7.7 VA | 6.2 VA | 97.9 ohms | ||
110 volts, 50 Hz, 120 volts, 60 Hz | 7.8 VA | 6.3 VA | 619 ohms | ||
240 volts, 50/60 Hz | 7.8 VA | 6.3 VA | 3400 ohms | ||
12 volts D-C | 4.6 Watts | 27.4 ohms | |||
24 volts D-C | 4.8 Watts | 97.9 ohms | |||
60 volts D-C | 4.3 Watts | 619 ohms |
Molding Material: Thermoplastic.
Ambient Temperature: -20°C to +50°C.
Relative Duty Cycle: 100%.
Degree of Protection: IP65 with connector (IP67 possible with accessories).
Certifications: This coil carries the UL certificate of compliance both the standard and Canadian certification. A copy of the certification is available here. The rating only applies to the coil and not the entire valve.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Insulation Class: F
Ambient Temperature: -20°C to +50°C.
Relative Duty Cycle: 100%.
Degree of Protection: IP65 with connector (IP67 possible with accessories).
Certifications: This coil carries the UL certificate of compliance both the standard and Canadian certification. A copy of the certification is available here. The rating only applies to the coil and not the entire valve.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Insulation Class: F
"E-Series" Coil - Option A - Intrinsically Safe
When related to solenoid valves, intrinsic safety means that the coil's current draw and resulting temperature is held to such a low level (when used with an approved safety barrier) that the valve no longer has the capability of igniting a mixture of flammable or combustible material, either during normal operation or under fault conditions. Typically, they are used in situations where fire and explosive hazards exist due to the presence of flammable gases, vapors or liquids, combustible dusts or easily ignitable fibers. Intrinsically safe coils and operators are sold as a matched set and must be ordered as V-564 (individual components are not available). Solenoid operator maximum pressure is 115 psi.
These operators are equipped with the standard V-562 nut but can be ordered with a V-567W bronze muffler nut (option L) or a V-562 side exhaust nut (option C).
These 24 VDC coils are approved according to EN 50 020 respectively DIN VDE 0170/0171 part 5 for hazardous location. Class I, groups A, B, C and D; Class II, groups E, F and G; Class III. This coil is an ISO 4400 DIN style pin pattern. A non-indicator, cord grip style cap is provided. A copy of the certification is available here. An approved cap (included) must be used when connecting to an electrical source. The longer tab is the ground (earth). Either shorter tab can be connected to hot (+) and the other connected to neutral (-).
These operators are equipped with the standard V-562 nut but can be ordered with a V-567W bronze muffler nut (option L) or a V-562 side exhaust nut (option C).
These 24 VDC coils are approved according to EN 50 020 respectively DIN VDE 0170/0171 part 5 for hazardous location. Class I, groups A, B, C and D; Class II, groups E, F and G; Class III. This coil is an ISO 4400 DIN style pin pattern. A non-indicator, cord grip style cap is provided. A copy of the certification is available here. An approved cap (included) must be used when connecting to an electrical source. The longer tab is the ground (earth). Either shorter tab can be connected to hot (+) and the other connected to neutral (-).
Molding Material: Thermoset resin.
Ambient Temperature: -20°C to +50°C.
Internal Diameter Orifice: 0.8mm
Relative Duty Cycle: 100%.
Degree of Protection: IP65 with connector.
Certifications: This coil carries the following certificate of compliance. The rating only applies to the coil/operator and not the entire valve.
Insulation Class: F
Electrical Characteristics: 21.6 - 28 VDC
"E-Series" Coil - Option H - High Temperature
The high temperature coils utilize a Form A/ISO 4400 DIN style connection (DIN 43650-A, 18 mm contact distance) with one ground tab and two voltage tabs. DIN caps are ordered as a separate line item. The coil is 30mm wide. Coil can be rotated in 45° increments on operator stem when space is available. An approved cap must be used when connecting to an electrical source. The longer tab is the ground (earth). Either shorter tab can be connected to hot (+) and the other connected to neutral (-).
Voltage | Pick-Up | Holding | Resistance | Spare Coil | |
---|---|---|---|---|---|
120 volts, 60 Hz | 6.8 VA | 741 ohms | |||
12 volts D-C | 4.5 Watts | 55 ohms |
Ambient Temperature: -20°C to +80°C.
Relative Duty Cycle: 100%.
Degree of Protection: IP65 with connector.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Insulation Class: H
"E-Series" Coil - Option J - 1/2" Conduit Mold-Over
The mold-over coil has a 1/2" NPT conduit connection with three 18" long wires. The coil is 22mm wide. Coil can be rotated in 90° increments on operator stem when space is available. When connecting to an electrical source either black wire can be connected to hot (+) and the other connected to neutral (-). The green wire is the ground (earth).
Voltage | Pick-Up | Holding | Resistance | Spare Coil | |
---|---|---|---|---|---|
24 volts, 60 Hz | 7.1 VA | 5.8 VA | 31.6 ohms | ||
48 volts, 60 Hz | 7.7 VA | 6.2 VA | 121 ohms | ||
120 volts, 60 Hz | 7.8 VA | 6.3 VA | 820 ohms | ||
240 volts, 60 Hz | 7.8 VA | 6.3 VA | 3400 ohms | ||
12 volts D-C | 4.6 Watts | 31.6 ohms | |||
24 volts D-C | 4.8 Watts | 121 ohms | |||
60 volts D-C | 4.3 Watts | 820 ohms |
Ambient Temperature: -20°C to +80°C.
Relative Duty Cycle: 100%.
Degree of Protection: IP65.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Insulation Class: F
"E-Series" Coil - Option M - 18" Flying Lead
The flying lead coil has two 18" long wires. The coil is 22mm wide. Coil can be rotated in 90° increments on operator stem when space is available. When connecting to an electrical source either black wire can be connected to hot (+) and the other connected to neutral (-).
Voltage | Pick-Up | Holding | Resistance | Spare Coil | |
---|---|---|---|---|---|
24 volts, 60 Hz | 7.1 VA | 5.8 VA | 27.4 ohms | ||
48 volts, 60 Hz | 7.7 VA | 6.2 VA | 97.9 ohms | ||
120 volts, 60 Hz | 7.8 VA | 6.3 VA | 619 ohms | ||
240 volts, 60 Hz | 7.8 VA | 6.3 VA | 3400 ohms | ||
12 volts D-C | 4.6 Watts | 27.4 ohms | |||
24 volts D-C | 4.8 Watts | 97.9 ohms | |||
60 volts D-C | 4.3 Watts | 619 ohms |
Ambient Temperature: -20°C to +50°C.
Relative Duty Cycle: 100%.
Degree of Protection: IP65.
Certifications: This coil carries the UL certificate of compliance both the standard and Canadian certification. A copy of the certification is available here. The rating only applies to the coil and not the entire valve.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Insulation Class: F
"E-Series" Coil - Option T - ATEX
The ATEX/IEC coil is molded with 3 meters of 3 wire cord. The wire has one green/yellow ground (earth) wire, one brown wire and one blue wire. Either the brown or blue wire can be hot (+) and the other neutral (-). The coil is 30mm wide. These coils are rated by the European standards PTB 03 ATEX 2018 X, IECEx PTB 04.0002X. See below for exact approvals. Coil can be rotated in 45° increments on operator stem when space is available.
Voltage | Pick-Up | Holding | Resistance | Spare Coil |
---|---|---|---|---|
24 volts D-C | 0.136 amps | 177 ohms |
Ambient Temperature: -20°C to +50°C.
Relative Duty Cycle: 100%.
Degree of Protection: IP65 (IP67 possible with accessories).
Certifications: This coil carries the ATEX/IEC certificate of conformity. A copy of the certification is available here. The rating only applies to the coil and not the entire valve.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Insulation Class: H
"E-Series" Coil - Option X - Explosion Proof
The explosion proof coils are a 1/2" NPT conduit connection with one green ground wire and two black wires. When connecting to an electrical source either black wire can be connected to hot (+) and the other connected to neutral (-). The green wire is the ground (earth). The coil is 36mm wide. On some valves this may interfere with mounting and a spacer may be used under the valve. These coils are rated explosion proof for Class I, Division 1, Groups A, B, C and D (gasoline vapors, etc.), Class II, Groups E, F, and G (coal, coke and grain dusts), Class III. See below for exact approvals. Other voltages not shown below are available. Coil can be rotated in 90° increments on operator stem when space is available.
Voltage | Pick-Up | Holding | Resistance | Spare Coil |
---|---|---|---|---|
120 volts, 60 Hz | 6.8 VA | 530 ohms | ||
12 volts D-C | 4.5 Watts | 31.6 ohms | ||
24 volts D-C | 4.6 Watts | 121 ohms | ||
240 volts, 60 Hz | 6.8 VA | 2345 ohms | V-593-4 |
Conduit Material: on V-593-1 thru -3, stainless steel. On V-593-4, zinc plated.
Ambient Temperature: -20°C to +60°C.
Relative Duty Cycle: 100%.
Degree of Protection: IP65 with connector (IP67 possible with accessories).
Certifications: This coil carries both a FM and CSA approval rating; CSA CLASS 2258 02, process control equipment for hazardous locations; FM CLASS 3600, 3611, 3615, 3810, hazardous (classified) location electrical equipment. A copy of the certification is available here. The rating only applies to the coil and not the entire valve.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Insulation Class: H
Commonly Asked Questions
Q: Can I use a piece of equipment approved for use in a Division 1 hazardous location in a Division 2 hazardous location?
A: Yes. If equipment has been approved for use in a Division 1 hazardous location, it can be used in a Division 2 hazardous location, providing it is in the same class and group.
A: Yes. If equipment has been approved for use in a Division 1 hazardous location, it can be used in a Division 2 hazardous location, providing it is in the same class and group.
Q: Can equipment approved for a Class I hazardous location be used in a Class II hazardous location?
A: No. Equipment used in Class I and Class II hazardous locations are made for different purposes. Equipment approved for Class I hazardous locations must contain an internal explosion, while Class II approved equipment must seal out dust. They are not interchangeable.
A: No. Equipment used in Class I and Class II hazardous locations are made for different purposes. Equipment approved for Class I hazardous locations must contain an internal explosion, while Class II approved equipment must seal out dust. They are not interchangeable.
"Classic" Operator & Coil - Standard
The "Classic" solenoid operators sturdy and tough construction with a 1/2" NPT conduit connection. The stem exhaust is tapped 10-32. Voltage must be specified when ordering valves that use this operator. If no voltage is specified, then 120/60 is provided. Other voltages not shown below are available. Coil can be rotated in any direction on operator stem when space is available. Caution must be used when rotating coil so not to untighten the stem from the adaptor block. Standard leads are 18", longer leads available on request. When connecting to an electrical source either black wire can be connected to hot (+) and the other connected to neutral (-).
Voltage | Pick-Up | Holding | Resistance | Operator | Spare Coil* | |
---|---|---|---|---|---|---|
24 volts, 60 Hz | 1.72 amps | 1.10 amps | 5.39 ohms | AY-38-4 | V-67-4 | |
120 volts, 60 Hz | 0.36 amps | 0.23 amps | 135 ohms | AY-38-11 | V-67-11 | |
240 volts, 60 Hz | 0.18 amps | 0.12 amps | 546 ohms | AY-38-17 | V-67-17 | |
12 volts D-C | 1.20 amps | 12.8 ohms | AY-38-5 | V-67-5 | ||
24 volts D-C | 0.58 amps | 61 ohms | AY-38-8 | V-67-8 |
Materials: Steel, stainless steel, thermoset polyester molded resin coil, Buna-N seat & O-Ring.
Repair Kit: RKPSV-1 includes plunger, spring & O-Ring.
Ambient Temperature: -4°F to +120°F.
Relative Duty Cycle: 100%.
Degree of Protection: NEMA 1.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Orifice Size: 3/64" base, 1/16" stem.
Insulation Class: B
*Coils: The encapsulated coils are UL approved. The coil is marked or embossed with QC130, QC155, or QC180. UL Document.
"Classic" Operator & Coil - Standard w/Tapped Exhaust
The "Classic" solenoid operators sturdy and tough construction with a 1/2" NPT conduit connection. The stem exhaust is tapped 1/8" NPTF. Voltage must be specified when ordering valves that use this operator. If no voltage is specified, then 120/60 is provided. Other voltages not shown below are available. Coil can be rotated in any direction on operator stem when space is available. Caution must be used when rotating coil so not to untighten the stem from the adaptor block. Standard leads are 18", longer leads available on request. When connecting to an electrical source either black wire can be connected to hot (+) and the other connected to neutral (-).
Voltage | Pick-Up | Holding | Resistance | Operator | Spare Coil* | |
---|---|---|---|---|---|---|
24 volts, 60 Hz | 1.72 amps | 1.10 amps | 5.39 ohms | AY-38T-4 | V-67-4 | |
120 volts, 60 Hz | 0.36 amps | 0.23 amps | 135 ohms | AY-38T-11 | V-67-11 | |
240 volts, 60 Hz | 0.18 amps | 0.12 amps | 546 ohms | AY-38T-17 | V-67-17 | |
12 volts D-C | 1.20 amps | 12.8 ohms | AY-38T-5 | V-67-5 | ||
24 volts D-C | 0.58 amps | 61 ohms | AY-38T-8 | V-67-8 |
Materials: Steel, stainless steel, thermoset polyester molded resin coil, Buna-N seat & O-Ring.
Repair Kit: RKPSV-1 includes plunger, spring & O-Ring.
Ambient Temperature: -4°F to +120°F.
Relative Duty Cycle: 100%.
Degree of Protection: NEMA 1.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Orifice Size: 3/64" base, 1/16" stem.
Insulation Class: B
*Coils: The encapsulated coils are UL approved. The coil is marked or embossed with QC130, QC155, or QC180. UL Document.
"Classic" Operator & Coil - DIN Style
The "Classic" DIN solenoid operator with a ISO 4400 din pattern connection (Form A, DIN 43650-A, 18 mm contact distance). DIN caps are ordered as a separate line item. The stem exhaust is tapped 10-32. Voltage must be specified when ordering valves that use this operator. If no voltage is specified, then 120/60 is provided. Other voltages not shown below are available. Coil can be rotated in any direction on operator stem when space is available. Caution must be used when rotating coil so not to untighten the stem from the adaptor block. An approved cap must be used when connecting to an electrical source. The longer tab is the ground (earth). Either shorter tab can be connected to hot (+) and the other connected to neutral (-).
Voltage | Pick-Up | Holding | Resistance | Operator | Spare Coil* | |
---|---|---|---|---|---|---|
120 volts, 60 Hz | 0.36 amps | 0.23 amps | 135 ohms | AY-38ED-11 | V-67ED-11 | |
240 volts, 60 Hz | 0.18 amps | 0.12 amps | 546 ohms | AY-38ED-17 | V-67ED-17 | |
12 volts D-C | 1.20 amps | 12.8 ohms | AY-38ED-5 | V-67ED-5 | ||
24 volts D-C | 0.58 amps | 61 ohms | AY-38ED-8 | V-67ED-8 |
Materials: Duroplast/thermoset resin, Buna-N seat & O-Ring.
Repair Kit: RKPSV-1 includes plunger, spring & O-Ring.
Ambient Temperature: -4°F to +120°F.
Relative Duty Cycle: 100%.
Degree of Protection: NEMA 4 & 4X with connector.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Orifice Size: 3/64" base, 1/16" stem.
*Coils: The encapsulated coils are UL approved. The coil is marked or embossed with QC130, QC155, or QC180. UL Document.
"Classic" Operator & Coil - Explosion Proof
The "Classic" explosion proof solenoid operators are sturdy and tough construction with a 1/2" NPT conduit connection. The stem exhaust is tapped 1/8"-27 NPT. Voltage must be specified when ordering valves that use this operator. If no voltage is specified, then 120/60 is provided. Other voltages not shown below are available. Coil can be rotated in any direction on operator stem when space is available. Caution must be used when rotating coil so not to untighten the stem from the adaptor block. The explosion proof operator carries the UL & CSA label for Class I, Division 1, Group C and D (gasoline vapors, etc.), Class II, Division 1, Groups E, F and G (coal , coke and grain dusts). Temperature code: T4A. Standard leads are 18". When connecting to an electrical source either black wire can be connected to hot (+) and the other connected to neutral (-). The green wire is the ground (earth). The housing of all "Classic" explosion proof solenoids cannot be rotated or serviced in the field. If coil orientation is not specified at time of order, the 1/2" conduit will be rotated towards the 2 port side of valve body.
Voltage | Pick-Up | Holding | Resistance | |
---|---|---|---|---|
24 volts, 60 Hz | 1.72 amps | 1.10 amps | 5.39 ohms | |
120 volts, 60 Hz | 0.36 amps | 0.23 amps | 135 ohms | |
240 volts, 60 Hz | 0.18 amps | 0.12 amps | 546 ohms | |
12 volts D-C | 1.20 amps | 12.8 ohms | ||
24 volts D-C | 0.58 amps | 61 ohms |
Materials: Steel, stainless steel, thermoset polyester molded resin coil, Buna-N seat & O-Ring.
Ambient Temperature: -4°F to +120°F.
Relative Duty Cycle: 100%.
Certifications: UL & CSA label for Class I, Division 1, Group C and D, Class II, Division 1, Groups E, F and G. CSA file number 087427_0_000. UL file number E37005
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Orifice Size: 3/64" base, 1/16" stem.
Insulation Class: B
Commonly Asked Questions
Q: Can I use a piece of equipment approved for use in a Division 1 hazardous location in a Division 2 hazardous location?
A: Yes. If equipment has been approved for use in a Division 1 hazardous location, it can be used in a Division 2 hazardous location, providing it is in the same class and group.
A: Yes. If equipment has been approved for use in a Division 1 hazardous location, it can be used in a Division 2 hazardous location, providing it is in the same class and group.
Q: Can equipment approved for a Class I hazardous location be used in a Class II hazardous location?
A: No. Equipment used in Class I and Class II hazardous locations are made for different purposes. Equipment approved for Class I hazardous locations must contain an internal explosion, while Class II approved equipment must seal out dust. They are not interchangeable.
A: No. Equipment used in Class I and Class II hazardous locations are made for different purposes. Equipment approved for Class I hazardous locations must contain an internal explosion, while Class II approved equipment must seal out dust. They are not interchangeable.
"Classic" Operator & Coil - Mold-Over
The "Classic" Mold-Over solenoid operator with a 1/2"-14 NPT conduit connection. The stem exhaust is tapped 10-32. Voltage must be specified when ordering valves that use this operator. If no voltage is specified, then 120/60 is provided. Other voltages not shown below are available. Coil can be rotated in any direction on operator stem when space is available. Caution must be used when rotating coil so not to untighten the stem from the adaptor block. Standard leads are 18", longer leads available on request. When connecting to an electrical source either black wire can be connected to hot (+) and the other connected to neutral (-). The green wire is the ground (earth).
Voltage | Pick-Up | Holding | Resistance | Operator | Spare Coil* | |
---|---|---|---|---|---|---|
120 volts, 60 Hz | 0.36 amps | 0.23 amps | 135 ohms | AY-38M-11 | V-67M-11 | |
240 volts, 60 Hz | 0.18 amps | 0.12 amps | 546 ohms | AY-38M-17 | V-67M-17 | |
12 volts D-C | 1.20 amps | 12.8 ohms | AY-38M-5 | V-67M-5 | ||
24 volts D-C | 0.58 amps | 61 ohms | AY-38M-8 | V-67M-8 |
Materials: Zinc plated steel hub, molded coil, Buna-N seat & O-Ring.
Repair Kit: RKPSV-1 includes plunger, spring & O-Ring.
Ambient Temperature: -4°F to +120°F.
Relative Duty Cycle: 100%.
Degree of Protection: NEMA 4 & 4X.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Orifice Size: 3/64" base, 1/16" stem.
*Coils: The encapsulated coils are UL approved. The coil is marked or embossed with QC130, QC155, or QC180. UL Document.