AAA Products International Inc.
7114 Harry Hines Blvd.
Dallas, Texas 75235
214-357-3851

Data for 120V

The 120V is a 3/8" subplate style, 2 position, spring return, solenoid operated valve with a twist locking solenoid override with a dust excluder nut on the solenoid exhaust. The spool is shifted by 50 to 160 psi internal pilot air derived from pressure in port 1 when the solenoid is energized. 50 to 160 psi must be maintained on port 1 to keep the spool shifted while the coil is energized, or when using the locking override. Twist the override clockwise to activate override. The spool is spring returned when the solenoid is de-energized. Valve must be used with a subplate style connection. See the dedicated subplate section or the stacking manifold section. See additional information on solenoid valve operation. The rear end cap is vented through the exhaust port 5 (EB), with the last o-ring omitted.

Details

Pressure: 50 to 160 psi on the main body of the valve when solenoid is internally piloted.
Vacuum: The valve cannot be vacuum operated when the solenoid is internally piloted.
Temperature: -20°F to 120°F ambient. Caution: If it is possible that the ambient temperature may fall below freezing, the medium must be moisture free to prevent internal damage or unpredictable behavior.
Mounting: The valve can be mounted in any orientation.
O-Rings: Viton.
Solenoid Seat: Buna-N.
Materials: Black anodized 2024-T3511 aluminum body, hard anodized aluminum spool, A380 aluminum end cap, composite gaskets, steel fasteners.
Flow: 73.9 SCFM, 1.6 Cv
Repair Kit: ERKV-3 & RKPSV-1.
3-Way or 5-Way: This valve is basically 4-way, it must be configured for external pilot (Option 'Z') for 5-way service by using ports 2 or 4 as an inlet, or 3-way service by plugging the unused port 2 or 4.
Fluid Media: Soft seal models are made for air, vacuum, and gases compatible with component materials. They should not be used with liquids.
AAA Products International