7114 Harry Hines Blvd.
Dallas, Texas 75235
214-357-3851
Data for 497VY
Details for 497VY
Vacuum: The valve cannot be vacuum operated when the solenoid is internally piloted.
Temperature: -20°F to 120°F ambient. Caution: If it is possible that the ambient temperature may fall below freezing, the medium must be moisture free to prevent internal damage or unpredictable behavior.
Mounting: The valve can be mounted in any orientation.
O-Rings: Viton.
Solenoid Seat: Buna-N.
Materials: TUFRAM® coated 6061-T6 aluminum body and adaptor, hard anodized aluminum spool, electroless nickel plated A380 aluminum end caps, nitrile gaskets, stainless steel fasteners.
Flow: 97.1 SCFM, 2.4 Cv
Repair Kit: RKV-440VY.
3-Way or 5-Way: This valve is basically 4-way, it must be configured for external pilot (Option 'Z') for 5-way service by using ports 2 or 4 as an inlet, or 3-way service by plugging the unused port 2 or 4.
Fluid Media: Soft seal models are made for air, vacuum, and gases compatible with component materials. They should not be used with liquids.
Weight: 3.5 lbs ± 5%.


"Classic" Operator & Coil - Explosion Proof
Voltage | Pick-Up | Holding | Resistance | |
---|---|---|---|---|
24 volts, 60 Hz | 1.72 amps | 1.10 amps | 5.39 ohms | ![]() |
120 volts, 60 Hz | 0.36 amps | 0.23 amps | 135 ohms | |
240 volts, 60 Hz | 0.18 amps | 0.12 amps | 546 ohms | |
12 volts D-C | 1.20 amps | 12.8 ohms | ||
24 volts D-C | 0.58 amps | 61 ohms |
Materials: Steel, stainless steel, thermoset polyester molded resin coil, Buna-N seat & O-Ring.
Ambient Temperature: -4°F to +120°F.
Relative Duty Cycle: 100%.
Certifications: UL & CSA label for Class I, Division 1, Group C and D, Class II, Division 1, Groups E, F and G. CSA file number 087427_0_000. UL file number E37005
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Orifice Size: 3/64" base, 1/16" stem.
Insulation Class: B
Commonly Asked Questions
A: Yes. If equipment has been approved for use in a Division 1 hazardous location, it can be used in a Division 2 hazardous location, providing it is in the same class and group.
A: No. Equipment used in Class I and Class II hazardous locations are made for different purposes. Equipment approved for Class I hazardous locations must contain an internal explosion, while Class II approved equipment must seal out dust. They are not interchangeable.
A: No. The requirement for explosion proof certification requires a high potential test that must be completed on the operator/valve.
A: No. The requirements for explosion proof require extremely tight fitting components. Rotating a canister after installation could rotate the stem out of the adaptor and cause leak or operation issues. Contact the factory for how to specify coil rotation/orientation when ordering. The standard 1/2" conduit will be rotated towards the 2 port side of valve body.
TUFRAM®
A special surface process called TUFRAM® can be applied to all aluminum and aluminum alloy parts giving them enhanced surface properties. These properties include improved corrosion resistance, abrasion resistance, chemical resistance, moisture resistance, increased hardness, USDA-approved and FDA-approved. This process is ideal for AAA valves that are used in very harsh environments. For example, wash down areas in food processing plants that use caustic solutions for clean-up, off shore oil platforms that are subject to salt water spray, chemical processing plants or valves that must mount outdoors. Please contact us for more information on the use of TUFRAM® L-4 on your application.
Tufram Information
General - Installation & Maintenance
Bulletin A-113: Operating & Maintenance Instructions.
Installation: Valve Fitting Installation.
General - O-Ring Information
Dash No. | O-ring Description | Temperature Rating |
---|---|---|
-2 | Silicone | -80°F to 400°F |
-3 | Viton for most aromatic gases | -20°F to 400°F, 600°F for short time |
-7 | Urethane, 70 Durometer | -65°F to 200°F |
-9 | Buna-N | -40°F to 250°F |
General - Lubrication, Standard
The shelf life of Magnalube-G regularly lasts for 10+ year intervals in closed packaging due to the extremely long operating life of the Elastomer-PTFE gelling agent and premium parafiinic mineral base oil. If the valve is stored for over 2 years, then a small reapplication of grease is suggested.
Magnalube-G Technical Document
Magnalube-G MSDS Document
An alternative grease for low temperature application, refer to Dow-55 grease.
