7114 Harry Hines Blvd.
Dallas, Texas 75235
214-357-3851
Data for SS12Z
Details
Vacuum: The five main ports can be operated on industrial vacuum to 28" Hg, based on a 30" barometer.
Temperature: -20°F to 120°F ambient. Caution: If it is possible that the ambient temperature may fall below freezing, the medium must be moisture free to prevent internal damage or unpredictable behavior.
Mounting: The spool is friction positioned so the valve must be mounted with the spool in a horizontal orientation.
O-Rings: Buna-N in main valve, Viton in control valve.
Solenoid Seat: Buna-N.
Materials: 356-T6 aluminum body aluminum body, hard anodized aluminum spool, A380 aluminum end caps, composite gaskets, steel fasteners.
Flow: 1627 SCFM, 37.8 Cv
Repair Kits: ERKV-16 & ERKV-3 & two RKPSV-1.
3-Way or 5-Way: This valve is basically 4-way, it must be configured for external pilot (Option 'Z') for 5-way service by using ports 2 or 4 as an inlet, or 3-way service by plugging the unused port 2 or 4.
Fluid Media: Soft seal models are made for air, vacuum, and gases compatible with component materials. They should not be used with liquids.


"Classic" Operator & Coil - Standard
Voltage | Pick-Up | Holding | Resistance | Operator | Spare Coil* | |
---|---|---|---|---|---|---|
24 volts, 60 Hz | 1.72 amps | 1.10 amps | 5.39 ohms | AY-38-4 | V-67-4 | ![]() |
120 volts, 60 Hz | 0.36 amps | 0.23 amps | 135 ohms | AY-38-11 | V-67-11 | |
240 volts, 60 Hz | 0.18 amps | 0.12 amps | 546 ohms | AY-38-17 | V-67-17 | |
12 volts D-C | 1.20 amps | 12.8 ohms | AY-38-5 | V-67-5 | ||
24 volts D-C | 0.58 amps | 61 ohms | AY-38-8 | V-67-8 |
Materials: Steel, stainless steel, thermoset polyester molded resin coil, Buna-N seat & O-Ring.
Repair Kit: RKPSV-1 includes plunger, spring & O-Ring.
Ambient Temperature: -4°F to +120°F.
Relative Duty Cycle: 100%.
Degree of Protection: NEMA 1.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Orifice Size: 3/64" base, 1/16" stem.
Insulation Class: B
*Coils: The encapsulated coils are UL approved. The coil is marked or embossed with QC130, QC155, or QC180. UL Document.
General - 1-1/2" & 2" Valve Operation
Normal assembly of all standard 1-1/2" & 2" valves is for internal pilot operation, in which the air pressure for shifting the large spool is internally tapped off the valve inlet. If the main spool is to handle pressures lower than 50 PSI or more than 150 PSI on
Normal assembly of all standard 1-1/2" & 2" valves is for internal pilot operation, in which the air pressure for shifting the large spool is internally tapped off the valve inlet. If the main spool is to handle pressures lower than 50 PSI or more than 150 PSI on solenoid models or from 50 to 250 psi on all other models, the valve should be factory ordered for "external pilot operation" by adding suffix "Z" after the regular model number. Or, the valve can easily be converted in the field to external piloting as described below. This pressure limitation applies to all 1-1/2" and 2" manual lever, solenoid, pilot or differential pilot valves.
Conversion to External Piloting: Remove the entire control valve from the main body and lay it aside. Install a 1/16"-27 NPT pipe plug in the treaded hole uncovered in the body mounting pad. Re-mount the control valve in the same orientation as before. Connect a pilot pressure air source (50 to 150 PSI on solenoid models and 50 to 250 psi on all other models) to the 1/4" NPTF external pilot port. This port is located on the side and near the top of the main body and stamped "EXT P", on the side opposite the MFC flow controls.

2 POSITION VALVES

2 POSITION VALVES

3 POSITION VALVES

3 POSITION VALVES
General - Installation & Maintenance
Bulletin A-113: Operating & Maintenance Instructions.
Installation: Valve Fitting Installation.
General - O-Ring Information
Dash No. | O-ring Description | Temperature Rating |
---|---|---|
-2 | Silicone | -80°F to 400°F |
-3 | Viton for most aromatic gases | -20°F to 400°F, 600°F for short time |
-7 | Urethane, 70 Durometer | -65°F to 200°F |
-9 | Buna-N | -40°F to 250°F |
General - Lubrication, Standard
The shelf life of Magnalube-G regularly lasts for 10+ year intervals in closed packaging due to the extremely long operating life of the Elastomer-PTFE gelling agent and premium parafiinic mineral base oil. If the valve is stored for over 2 years, then a small reapplication of grease is suggested.
Magnalube-G Technical Document
Magnalube-G MSDS Document
An alternative grease for low temperature application, refer to Dow-55 grease.