Data for SS8EDT
The SS8EDT is a 1" NPTF side ported, 2 position, double solenoid operated valve with 1/8" NPTF tapped solenoid vent/exhaust. The spool is shifted by 25 to 160 psi internal pilot air derived from pressure in port 1 when the solenoid is energized. The spool is returned when the solenoid is de-energized and the opposite solenoid is energized. See additional information on solenoid valve operation. Coil is a DIN coil with an ISO 4400 connector pattern. Coil requires an ISO 4400 style DIN cap. Standard voltage is 120/60, indicate other voltages (i.e. 12VDC, 24VDC, 240/60 etc.).
Details
Pressure: 25 to 160 psi on the main body of the valve when solenoid is internally piloted.
Vacuum: The valve cannot be vacuum operated when the solenoid is internally piloted.
Temperature: -20°F to 120°F ambient. Caution: If it is possible that the ambient temperature may fall below freezing, the medium must be moisture free to prevent internal damage or unpredictable behavior.
Mounting: The spool is friction positioned so the valve must be mounted with the spool in a horizontal orientation.
O-Rings: Buna-N.
Solenoid Seat: Buna-N.
Materials: Black anodized 356-T6 aluminum body, hard anodized aluminum spool, A380 aluminum end caps, composite gaskets, steel fasteners.
Flow: 478 SCFM, 11.1 Cv
Repair Kit: ERKV-8 & two RKPSV-1.
3-Way or 5-Way: This valve is basically 4-way, it must be configured for external pilot (Option 'Z') for 5-way service by using ports 2 or 4 as an inlet, or 3-way service by plugging the unused port 2 or 4.
Fluid Media: Soft seal models are made for air, vacuum, and gases compatible with component materials. They should not be used with liquids.
Vacuum: The valve cannot be vacuum operated when the solenoid is internally piloted.
Temperature: -20°F to 120°F ambient. Caution: If it is possible that the ambient temperature may fall below freezing, the medium must be moisture free to prevent internal damage or unpredictable behavior.
Mounting: The spool is friction positioned so the valve must be mounted with the spool in a horizontal orientation.
O-Rings: Buna-N.
Solenoid Seat: Buna-N.
Materials: Black anodized 356-T6 aluminum body, hard anodized aluminum spool, A380 aluminum end caps, composite gaskets, steel fasteners.
Flow: 478 SCFM, 11.1 Cv
Repair Kit: ERKV-8 & two RKPSV-1.
3-Way or 5-Way: This valve is basically 4-way, it must be configured for external pilot (Option 'Z') for 5-way service by using ports 2 or 4 as an inlet, or 3-way service by plugging the unused port 2 or 4.
Fluid Media: Soft seal models are made for air, vacuum, and gases compatible with component materials. They should not be used with liquids.


"Classic" Operator & Coil - DIN Style w/Tapped Exhaust
The "Classic" DIN solenoid operator with a ISO 4400 din pattern connection (Form A, DIN 43650-A, 18 mm contact distance). DIN caps are ordered as a separate line item. The stem exhaust is tapped 1/8" NPTF. Voltage must be specified when ordering valves that use this operator. If no voltage is specified, then 120/60 is provided. Other voltages not shown below are available. Coil can be rotated in any direction on operator stem when space is available. Caution must be used when rotating coil so not to untighten the stem from the adaptor block. An approved cap must be used when connecting to an electrical source. The longer tab is the ground (earth). Either shorter tab can be connected to hot (+) and the other connected to neutral (-).
Voltage | Pick-Up | Holding | Resistance | Operator | Spare Coil* | |
---|---|---|---|---|---|---|
120 volts, 60 Hz | 0.36 amps | 0.23 amps | 135 ohms | AY-38EDT-11 | V-67ED-11 | ![]() |
240 volts, 60 Hz | 0.18 amps | 0.12 amps | 546 ohms | AY-38EDT-17 | V-67ED-17 | |
12 volts D-C | 1.20 amps | 12.8 ohms | AY-38EDT-5 | V-67ED-5 | ||
24 volts D-C | 0.58 amps | 61 ohms | AY-38EDT-8 | V-67ED-8 |
Materials: Duroplast/thermoset resin, Buna-N seat & O-Ring.
Repair Kit: RKPSV-1 includes plunger, spring & O-Ring.
Ambient Temperature: -4°F to +120°F.
Relative Duty Cycle: 100%.
Degree of Protection: NEMA 4 & 4X with connector.
Voltage Tolerance: ± 10%.
Resistance Tolerance: ± 8% at 20°C.
Orifice Size: 3/64" base, 1/16" stem.
*Coils: The encapsulated coils are UL approved. The coil is marked or embossed with QC130, QC155, or QC180. UL Document.
General - O-Ring Information
Unless otherwise specified, all 1/4" and 3/8" soft seal valves come standard with Viton O-rings and all 1/2", 3/4", 1", 1-1/2" and 2" soft seal valves come standard with Buna-N O-rings. If a different material is required, use the dash numbers following the basic valve numbering code. For example, model RY3G-2 will have Silicone O-rings installed for a low temperature application. On valves larger than 1" consult factory on availability of O-ring materials. Additional O-ring material information.
Dash No. | O-ring Description | Temperature Rating |
---|---|---|
-2 | Silicone | -80°F to 400°F |
-3 | Viton for most aromatic gases | -20°F to 400°F, 600°F for short time |
-7 | Urethane, 70 Durometer | -65°F to 200°F |
-9 | Buna-N | -40°F to 250°F |
We are constantly researching O-ring materials to evaluate performance and durability in the AAA valve product line. Above is a compilation of the most commonly requested O-ring materials and the associated dash number. If you have a particular application that requires an O-ring material that is not listed, please contact us. Since we utilize standard O-ring dimensions in our valves, we can respond to the most obscure O-ring material request.
General - Lubrication, Standard
All valves are pre-lubricated at the factory using Magnalube-G Teflon based all purpose grease. Valves are suitable for, and perform best in a non-lube service. For long life, use an air line filter/lubricator installed no further than 10-ft. from the valve. The filter should be rated 25 pm or finer. Use a good grade of petroleum base lubricating oil no heavier than SAE 10W. DO NOT OVER-LUBRICATE. This could cause the spool to stick. CAUTION! Do not use questionable fluids in air line lubricators. Do not use petroleum oil with detergent additives. Detergents, volatile or aromatic fluids may swell rubber seals in valves and cylinders. Never use cooking or vegetable oil as a lubricant. When cleaning AAA valves after extended service, lubricate the valve spool with AAA high film strength grease, or, use O-ring grease which is usually available from supply houses which sell O-rings. Magnalube-G is included in all valve repair kits for proper valve maintenance. If an additional amount of Magnalube-G grease is required, a 0.75 ounce tube is available under part number VGK-3. Never use any kind of oil, cup grease, or automobile chassis lubricant.
The shelf life of Magnalube-G regularly lasts for 10+ year intervals in closed packaging due to the extremely long operating life of the Elastomer-PTFE gelling agent and premium parafiinic mineral base oil. If the valve is stored for over 2 years, then a small reapplication of grease is suggested.
Magnalube-G Technical Document
Magnalube-G MSDS Document
The shelf life of Magnalube-G regularly lasts for 10+ year intervals in closed packaging due to the extremely long operating life of the Elastomer-PTFE gelling agent and premium parafiinic mineral base oil. If the valve is stored for over 2 years, then a small reapplication of grease is suggested.
Magnalube-G Technical Document
Magnalube-G MSDS Document
An alternative grease for low temperature application, refer to Dow-55 grease.